ECG.Net         net2.0

 Ready to use Microsoft.Net software components for ECG (ElectroCardiography) applications.

 Each component comes with:

  • "EcgSoft.ComponentName.dll" library file
  • "EcgSoft.ComponentName.chm" file for MSDN style documentation
  •  A sample project to demonstrate the use of the component.

 Please contact us for pricing and any other information on a specific component. We can also develop components as per your specifications.  

------------------------------------------------------------

SCP-ECG FILE READ/WRITE

 Scp-Ecg File Read/Write is a Microsoft.Net software component for  reading and writing ECG data in the SCP-ECG standard.

Features

  • Suitable for rest and stress ECG recordings
  • Different features can be added upon user request
  • No compression or first difference at present implementation
  • Check www.openecg.net for more details on the standard.
  • Download free version

------------------------------------------------------------

BEAT (QRS) DETECTOR

 QRS detector is a Microsoft.Net software component for robust detection of heart beats in an ECG signal.

Features

  • Tested and verified on the MIT-BIH database
  • Sensitivity: %99.8
  • Specifity: %99.7
  • Detection delay: 240 ms
  • Heart rate calculation
  • Adaptive threshold to minimize false positives
  • Easy to use and integrate

------------------------------------------------------------

ONLINE BASELINE FILTER

 Online Baseline Filter is a Microsoft.Net software component intended to be used as a high pass filter in  removing baseline wandering  from an ECG signal in near real time.

Features

  • 3db cut-off frequency: 0.67 Hz
  • Filter delay: 3 seconds
  • Forward and backward filtering in a window to achieve linear phase response.

------------------------------------------------------------

ADAPTIVE 50 Hz POWER LINE FILTER

 Adaptive 50 Hz Power Line Filter is a Microsoft.Net software component for removing power line interference on the ECG signal

Features

  • Adaptive
  • Estimates and subtracts 50Hz from the ECG signal

------------------------------------------------------------

OFFLINE ECG FILTER SET

 A set of baseline, EMG and power line filters for offline ECG signal filtering.

Features

  • Adaptable to most sampling rates
  • All filters share a common API
  • 50 or 60 Hz selectable for power line filter

------------------------------------------------------------

ARRHYTHMIA PREPROCESSOR

 Detects  abnormal beats and outputs them to Arrhythmia Classifier for further classification.

------------------------------------------------------------

ARRHYTHMIA CLASSIFIER

 Classifies and produces statements describing the type of Arrhythmia. Input beats are provided by the Arrhythmia Preprocessor.

------------------------------------------------------------

ECG GUI ENGINE

 ECG GUI engine is a Microsoft.Net software component for displaying and viewing ECG signals on a child form.

Features

  • Main component of the ECG Viewer
  • Amplitude-time scaling
  • Various view formats
  • Selectable trace,text and grid colors
  • On screen ECG measurement tool

------------------------------------------------------------

TREADMILL CONTROL

 Treadmill control is a Microsoft.Net software component for controlling treadmills in stress ECG testing

Features

  • Track Master compatible command set
  • Speed, elevation, start and stop commands

------------------------------------------------------------

TREADMILL PROTOCOL EDITOR GUI

 Treadmill protocol editor GUI is a Microsoft.Net software component for editing and  creating protocols in stress ECG testing

Features

  • Speed, slope, duration and step type parameters
  • Comes with most of the popular protocols

------------------------------------------------------------

BLOOD PRESSURE DEVICE CONTROL

 BP device control is a Microsoft.Net software component for controlling and communicating with and external BP device  in stress ECG testing

Features

  • SunTechTango BP device compatible